Bioremediation Jet Fuel

Print

Bioremediation Products                                                      Final_logo


Bioremediation of Jet Fuel

During a facilities upgrade at a major international airport, a number of underground storage tanks containing Jet A fuel had to be removed.  Overfills had impacted soil and groundwater.  A program was developed to remove and dispose of contaminated soil and to biologically treat the groundwater remaining in the pit excavation.

The project consisted of three phases.  In phase one, all the tanks and approximately 16,000 tons of contaminated soil were removed and disposed.  In phase two, approximately 18,000 gallons of floating Jet A fuel and wastewater were removed.  In phase three, M1000H* microbes and nutrients were applied to the remaining groundwater within the tank excavation to eliminate the final dissolved phase hydrocarbons.  The bacteria were allowed to work for approximately three weeks.  During this time, any free floating hydrocarbons were collected and removed.  Once completed, the excavation was backfilled and the groundwater was monitored for an additional four months to comply with state requirements for risk based clean-up criteria.  Grab samples were collected from three points around the excavation. Results are noted in the table below.

Data reported in micrograms per liter.

 

Contaminant

#1 Pre-treat

#1 Post

treat

#2 Pre-treat

#2 Post treat

#3 Pre-treat

#3 Post treat

Benzene

1.1

.50U

6.0 J

.50U

0.90

.50U

Toluene

.50U

.50U

2.5U

.50U

.50U

.50U

Ethylbenzene

.50U

.50U

2.7 J

.50U

.50U

.50U

Xylenes

.50U

.50U

12 J

.50U

.50U

.50U

Naphthalene

10 U

10 U

7.8 J

11 U

13 U

0.5 J

Acenaphthene

10 U

10 U

11 U

11 U

13 U

11 U

Fluorene

10 U

10 U

1.3 J

11 U

13 U

0.6 J

Phenanthrene

10 U

10 U

0.8 J

11 U

13 U

11 U

Anthracene

10 U

10 U

0.2 J

11 U

13 U

11 U

Fluoranthene

10 U

10 U

0.8 J

11 U

13 U

0.7 J

Pyrene

0.3 J

10 U

0.6 J

11 U

0.4 J

0.8 J

Benzo(a)anthracene

10 U

10 U

0.3 J

11 U

13 U

11 U

Chrysene

10 U

10 U

0.2 J

11 U

13 U

11 U

Benzo(b)fluoranthene

10 U

10 U

0.4 J

11 U

13 U

11 U

Note:  U=compound not detected at stated method detection limit

J=reported concentration is an estimated value

 

Micro-Bac International, Inc. 3200 N. IH 35, Round Rock, Texas 78681-2410  Toll Free 877-559-1800 512-310-9000, Fax 512-310-8800